TM Master v2 can be configured to import counter readings from external counter systems. Here is how to do it:
1.You need to configure your counter/automation system to export the counter readings to a folder on your network, where users of TM Master V2 can reach them. Consult your supplier of your counter system on how to do this.
System Settings in TM Master V2
2.Log on TM Master v2 using an admin account.
3.Click [System] → [Settings] →”General” tab
4.Select the ‘Running Hours’ sub tab on the bottom right of the view.
5.Select the appropriate counter system, which is exporting the readings file.
6.Select the path to where the counter file is placed.
Enter the counter systems tag/code on the corresponding components in TM Master V2.
7.Double click the component in the counter list (or component module]
8.Click the “Additional counters” tab.
9.Double click the correct counter in the upper left pane
10.Tick the “Automated update” check box.
11.Enter the tag that identifies this component in the import file.
12.Click [Save]
The steps 6-10 must be done for all the components that will import counter readings.